Analysis of walls in gabions, weirs of simple concrete and weirs in GABIONS in
static ad seismic conditions.
Safety factors: in case of
tipping
over;
sliding;
limit
load;
global
stability;
siphoning.
Micro-piles
GDW makes the calculation of gabions on micro-piles. It is possible to evaluate
the safety coefficient with vertical and horizontal limit load.
The software includes the use of micro-piles: Radice and Tubifix.
For Tubifix mini-piles it is possible to manage the type of injection (single
or repeated).
The analysis can be carried out under drained and undrained conditions.
The calculation of the horizontal limit load can be made using both the
free-head rotation model and the locked-head rotation model.
Safety factor:
vertical limit load;
horizontal
limit load;
micro-pile
breaking mechanism. |
|
|
|
|